Serving our customers with quality and safety first.
3.03in. ⁓3-1/32"
2.625in. single mounting facility
1.32in. single mounting facility
2.56in.
2.16in.
0.196in. single mounting facility
support AV8 aircraft
4 unthreaded hole single mounting facility
polarized
rectangular single mounting facility
50.0 amperes dc motor load
100.0 amperes dc inductive load
100.0 amperes dc resistive load
28.0 dc
drawing: contactor - spdt 100 amp, 28vdc sidestable
s central studs are 1/4-28 UNF-2A; 2 near lower edge: polarized: 6-32 UNC-2A; bottom is insulation plate: glass filled polyester; terminals are glass seal copper core stinless (nickel plated per QQ-N-290) ; cover: aluminum 6061 (nickel plate) ; base header: brass (nickel plate) ; continuous cycle
1 screw ground
5 threaded stud contacts
1EA
2.16 inches maximum
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
Used on support av8 aircraft. s central studs are 1/4-28 unf-2a; 2 near lower edge: polarized: 6-32 unc-2a; bottom is insulation plate: glass filled polyester; terminals are glass seal copper core stinless (nickel plated per qq-n-290) ; cover: aluminum 6061 (nickel plate) ; base header: brass (nickel plate) ; continuous cycle drawing: contactor - spdt 100 amp, 28vdc sidestable 2.16" overall width 3.03" overall length
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.