RY-18W-K

RY18WK Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. RY-18W-K specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.795in. ⁓51/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.472in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.386in.

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

1.6 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

18.0 volts dc 25 deg celsius single winding

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.386 inches maximum

What is the NSN for RY-18W-K?

5945-01-356-6479

What's the federal classification of RY-18W-K?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-356-6479 RELAY,ELECTROMAGNETIC

0.386" overall width 0.795" overall length

NIIN
013566479
NIIN Date
04/08/92
Schedule B
 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
8 X 4 X 5
QUP
Historical Price
$11.60 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 84801-18000 Cage 38047
2. RY-18WK Cage 31918

Major End Users Countries and entities

  • - Department of The Navy 
  • - Greece 
  • - Turkey 

Availability for RY-18W-K A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

RY-18W-K / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.