Datasheet. REBC21D-1001CB specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.718in. ⁓1-23/32"

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

0.625in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.010in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.025in.

Mounting Slot Width
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.

0.150in. single mounting facility

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

stratolifter C-135 aircraft

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

15000.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

3 slotted hole single mounting facility

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

polarized

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

triangle single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

2.00 seconds fixed release time

Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.

1.396in. single mounting facility and 1.446in. single mounting facility

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

4.0 amperes ac motor load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

8.0 amperes ac inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes ac lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

13 pin all functions

Answers.

When was the most recent contract awarded?

On 05/13/2015 under contract SPE7M515M8167 for qty 16

What quantity is this sold in?

1EA

What is the overall width?

1.025 inches maximum

What is the NSN for REBC21D-1001CB?

5945-01-486-9435

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of REBC21D-1001CB?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-486-9435 RELAY,ELECTROMAGNETIC

Used on stratolifter c-135 aircraft. 1.025" overall width 1.718" overall length

NIIN
014869435
NIIN Date
07/19/01
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$774.05 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. REBC210D-2001CB Cage 99699
2. REBC210D-1001CB Cage 99699

Major End Users Countries and entities

  • - Department of The Air Force 

Availability for REBC21D-1001CB A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

REBC21D-1001CB / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.