Serving our customers with quality and safety first.
1.718in. ⁓1-23/32"
1.446in. single mounting facility
0.525in.
0.200in.
0.150in. single mounting facility
metal
hermetic
moderately rugged
1
general
1
320.0 ohms single winding
continuous
2 slotted hole single mounting facility
general purpose warehouse
0.180 cubicin.
IN-Line single mounting facility
2 pole, double throw, one position momentary
0.01 seconds fixed operate time
0.01 seconds fixed release time
28.0 volts dc 25 deg celsius single winding
10.0 amperes dc resistive load
28.0 dc
81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
8 pin all functions
96906-MS27401 government standard
1EA
0.200 inches maximum
Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.200" overall width 1.718" overall length
1. | MIL-PRF-6106 | Cage 81349 |
2. | MIL-R-6106 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.