Serving our customers with quality and safety first.
1.718in. ⁓1-23/32"
1.396in. single mounting facility and 1.446in. single mounting facility
1.425in.
0.525in.
0.150in. single mounting facility
metal
hermetic
moderately rugged
400.0
1
specific
1
continuous
air
2 slotted hole single mounting facility
general purpose warehouse
polarized
1.285 cubicin.
IN-Line single mounting facility
2 pole, double throw, one position momentary
feat
0.015 seconds fixed operate time
0.05 seconds fixed release time
115.0 volts ac 25 deg celsius single winding
4.0 amperes ac motor load and 4.0 amperes dc motor load
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
115.0 ac and 28.0 dc
failure rate level 3.0 percent per 10, 000 cycles
terminal surfaces gold
gold
81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
8 pin all functions
96906-MS27401 government standard
1EA
0.525 inches maximum
Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
failure rate level 3.0 percent per 10, 000 cycles 0.525" overall width 1.718" overall length
1. | M83536/11-002L | Cage 81349 |
2. | MIL-PRF-83536/11 | Cage 81349 |
3. | M83536/11-002L | Cage 74703 |
4. | M83536/11-002L | Cage 1WL60 |
5. | M83536/11-002 | Cage 81349 |
6. | MIL-PRF-83536/11B | Cage 81349 |
7. | MIL-R-6106 | Cage 81349 |
8. | MS27401-8U | Cage 96906 |
9. | MS27401-16 | Cage 96906 |
10. | MIL-R-83536/11 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.