MS27401-36P

MS2740136P Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. MS27401-36P specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.698in. and 1.718in. ⁓1-23/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.396in. single mounting facility and 1.446in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.105in. and 1.125in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.505in. and 0.525in.

Mounting Slot Width
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.

0.140in. single mounting facility and 0.160in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 slotted hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

30.0 milliamperes ac single winding

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.02 seconds fixed operate time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.05 seconds fixed release time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

115.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

4.0 amperes ac motor load and 4.0 amperes dc motor load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

8.0 amperes ac inductive load and 8.0 amperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load and 10.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes ac lamp load and 2.0 amperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

1.0 percent per 10, 000 cycles failure rate

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-83536 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-83536/11 government specification

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.505 inches minimum and 0.525 inches maximum

What is the NSN for MS27401-36P?

5945-01-308-2060

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of MS27401-36P?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-308-2060 RELAY,ELECTROMAGNETIC

1.0 percent per 10, 000 cycles failure rate 0.505" overall width 1.698" overall length

NIIN
013082060
NIIN Date
09/24/89
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
13.000lbs
Item Dimensions
17 X 5 X 11
QUP
Historical Price
$244.40 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MS27401-30 Cage 96906
2. MS27401-36 Cage 96906
3. MS27401-36U Cage 96906
4. M83536/11-007L Cage 81349
5. MIL-PRF-83536/11 Cage 81349
6. 556-7015832-014 Cage 53711
7. H791-3905-014 Cage 96169
8. 945336-30 Cage 06481
9. 3020318-002 Cage 53711
10. JA-D4K-103 Cage 58657
11. JADAK Cage 58657
12. 2756A/455-0603-006 Cage 94756
13. JA-D4K Cage 99699
14. MIL-PRF-6106 Cage 96906
15. MIL-R-6106 Cage 96906
16. MS27401-30P Cage 96906
17. MIL-R-6106 Cage 81349
18. M83536/11-007M Cage 81349
19. MS27401-36X Cage 96906
20. MIL-R-83536/11 Cage 81349

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - Federal Aviation Administration 
  • - National Weather Service 
  • - Poland 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Australia 
  • - Canada 
  • - France 
  • - Republic of Korea 
  • - United Kingdom 
  • - Netherlands 
  • - Portugal 
  • - Norway 
  • - Greece 
  • - Turkey 
  • - Nato Maintenance And Supply Agency 

Availability for MS27401-36P A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

MS27401-36P / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.