Datasheet. MHYU-12A115VAC specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.953in. ⁓1-61/64"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.562in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.812in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.265in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.120in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

40.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

ciruclar single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

300.0 milliamperes dc single winding

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.005 seconds fixed release time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.0100 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

12.0 volts dc 25 deg celsius single winding

Angle Between Adjacent Mounting Facilities
A measurement of the angle between adjacent mounting facilities.

125.0 radians single mounting facility

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 29.0 dc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

14 tab, solder lug all functions

Answers.

What is the overall width?

1.265 inches

What is the NSN for MHYU-12A115VAC?

5945-01-485-5471

What's the federal classification of MHYU-12A115VAC?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-485-5471 RELAY,ELECTROMAGNETIC

1.265" overall width 1.953" overall length

NIIN
014855471
NIIN Date
05/30/01
Schedule B
 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Italy 

Availability for MHYU-12A115VAC A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

MHYU-12A115VAC / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.