Datasheet. M39016/9-060M specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.780in. ⁓25/32"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.280in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

0.370in. ⁓3/8"

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic and vibration proof and shock proof

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

390.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 terminal single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

spcl

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

12.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

1.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

lead lg 0.500 in. min., temp range m 65 deg c to p 125 deg c

Special Test Features
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.

failure rate level /percent per 10000 cycles/ 0.1 percent

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 wire lead all functions

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-39016/9 government specification

Answers.

What is the NSN for M39016/9-060M?

5945-01-290-3790

How is this classified for shipping?

Schedule B number: 8536410020
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of M39016/9-060M?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-290-3790 RELAY,ELECTROMAGNETIC

lead lg 0.500 in. min., temp range m 65 deg c to p 125 deg c 0.780" overall length

NIIN
012903790
NIIN Date
12/09/88
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MIL-PRF-39016/9 Cage 81349
2. MIL-R-39016/9 Cage 81349
3. 10132685 Cage A486G
4. MIL-PRF-39016/9 Cage 81349
5. MIL-R-39016/9 Cage 81349
6. 10132685 Cage A486G

Major End Users Countries and entities

  • - Finland 
  • - Spain 
  • - Canada 

Availability for M39016/9-060M A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

M39016/9-060M / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.