Serving our customers with quality and safety first.
1.780in. ⁓1-25/32"
0.370in. ⁓3/8"
moderately rugged
2
general
2
120.0 ohms single winding
continuous
air
7 terminal single mounting facility
general purpose warehouse
latching contacts
1 pole, double throw, one position momentary
feat
0.0015 seconds fixed operate time
6.0 volts dc 25 deg celsius single winding
500.0 milliamperes ac resistive load and 1.0 amperes dc resistive LOAD200.0 milliamperes dc inductive LOAD100.0 milliamperes dc lamp load
115.0 ac and 28.0 dc
failure rate 1.0 percent per 10, 000 cycles
81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
7 wire hook all functions
81349-MIL-R-39016/8 government specification
1EA
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
failure rate 1.0 percent per 10, 000 cycles 1.780" overall length
1. | MIL-PRF-39016/8 | Cage 81349 |
2. | 421-6 | Cage 11532 |
3. | C1909-1 | Cage 81755 |
4. | 421-6 | Cage 24176 |
5. | M39016/8-015P | Cage 81349 |
6. | MIL-R-39016/8 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.