Serving our customers with quality and safety first.
0.280in. ⁓9/32"
0.275in. and 0.335in. ⁓11/32"
hermetic
60.0 and 400.0
2
2
61.0 ohms first winding
continuous
1 terminal single mounting facility
2 pole, double throw, both positions maintained
feat
0.002 seconds fixed operate time
5.0 volts dc 25 deg celsius all windings
500.0 milliamperes ac resistive load
115.0 ac
failure rate 1.0 percent per 10.000 cycles
terminal surfaces gold
gold
81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
9 wire lead all functions
MIL-R-81349-39016/29 government specification
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
failure rate 1.0 percent per 10.000 cycles 0.280" overall length
1. | MIL-PRF-39016/29 | Cage 81349 |
2. | M39016/29-055L | Cage 81349 |
3. | MIL-R-39016 | Cage 81349 |
4. | MIL-PRF-39016 | Cage 81349 |
5. | MIL-R-39016/29 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.