Serving our customers with quality and safety first.
0.280in. ⁓9/32"
0.370in. ⁓3/8"
hermetic
2
2
2.0 kilohms all windings
continuous
1 terminal single mounting facility
2 pole, double throw, one position momentary
0.002 seconds fixed operate time
26.5 volts dc 25 deg celsius all windings
1.0 amperes dc resistive load
28.0 dc
81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
10 wire lead all functions
81349-MIL-R-39016/29 government specification
Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.280" overall length
1. | MIL-PRF-39016/29 | Cage 81349 |
2. | MIL-R-39016/29 | Cage 81349 |
3. | M39016/29-036L | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.