Datasheet. M39016/13-060R specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.062in. ⁓1-1/16"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

0.850in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.320in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.310in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

vibration resistant

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.096in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

0.125 amperes ac resistive load and 2.000 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

0.100 amperes dc lamp load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

0.300 amperes dc inductive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

9 wire lead all functions

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

96906-MIL-R-39016/13m government specification

Answers.

What is the overall width?

0.310 inches maximum

What is the NSN for M39016/13-060R?

5945-01-335-4907

How is this classified for shipping?

Schedule B number: 8536490050
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of M39016/13-060R?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-335-4907 RELAY,ELECTROMAGNETIC

0.310" overall width 1.062" overall length

NIIN
013354907
NIIN Date
03/10/91
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Taiwan, Province of China 

Availability for M39016/13-060R A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

M39016/13-060R / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.