Serving our customers with quality and safety first.
0.493in. ⁓1/2"
0.275in. and 0.335in. ⁓11/32"
hermetic and salt spray resistant
moderately rugged
pacer dawn
1
general
1
continuous
1 PLUG-In terminal single mounting facility
general purpose warehouse
0.043 cubicin.
2 pole, double throw, one position momentary
feat
0.002 seconds fixed release time
0.004 seconds fixed operate time
26.5 volts dc 25 deg celsius single winding
200.0 milliamperes dc inductive load
500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load
100.0 milliamperes dc lamp load
115.0 ac and 28.0 dc
failure rate 3.0
81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
10 pin all functions
81349-MIL-R-39016/11 government specification
Schedule B number: 8536490050
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
Used on pacer dawn. failure rate 3.0 0.493" overall length
1. | MIL-PRF-39016/11 | Cage 81349 |
2. | MIL-R-39016/11 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.