M39016/10-023L

M3901610023L Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. M39016/10-023L specification

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.375in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

0.275in. and 0.335in. ⁓11/32"

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

4.0 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 terminal single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, double throw, one position momentary

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.0025 seconds fixed release time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.004 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

26.5 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

0.1 amperes dc lamp load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

0.2 amperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

1.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

failure rate level 3.0 pct, lead length 1.500 in.

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

5 wire lead all functions

Answers.

What is the NSN for M39016/10-023L?

5945-01-189-7532

How is this classified for shipping?

Schedule B number: 8536410020
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of M39016/10-023L?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-189-7532 RELAY,ELECTROMAGNETIC

failure rate level 3.0 pct, lead length 1.500 in.

NIIN
011897532
NIIN Date
09/20/84
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MIL-PRF-39016/10 Cage 81349
2. MIL-R-39016/10 Cage 81349

Major End Users Countries and entities

  • - France 
  • - Germany 
  • - United Kingdom 
  • - Italy 

Availability for M39016/10-023L A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

M39016/10-023L / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.