Datasheet. M39016-25-028L specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.375in. ⁓3/8"

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

0.370in. ⁓3/8"

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

an/TSQ-111

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

specific

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

4.0 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 terminal single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

coil voltage suppression and polarized

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

0.161 cubicin.

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, double throw, one position momentary

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.004 seconds fixed operate time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.0075 seconds fixed release time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

26.5 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

200.0 milliamperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes ac resistive load and 1.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

failure rate level 0.1 percent per 10000 cycles

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

5 wire lead all functions

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-39016/25 government specification

Answers.

What quantity is this sold in?

1EA

What is the NSN for M39016-25-028L?

5945-01-222-9125

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of M39016-25-028L?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-222-9125 RELAY,ELECTROMAGNETIC

Used on an/tsq-111. failure rate level 0.1 percent per 10000 cycles 0.375" overall length

NIIN
012229125
NIIN Date
12/19/85
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
4 X 4 X 4
QUP
Historical Price
$522.80 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. M39016/25-036M Cage 81349
2. MIL-PRF-39016/25 Cage 81349
3. M3916/25-036L Cage 81349
4. M39016/25-036L Cage 81349
5. M39016/26-036P Cage 81349
6. MIL-R-39016/26 Cage 81349
7. MIL-R-39016/25 Cage 81349
8. M39016/25-036P Cage 81349

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Army 
  • - Department of The Air Force 
  • - Poland 
  • - Spain 
  • - Turkey 

Availability for M39016-25-028L A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

M39016-25-028L / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.