L40207

L40207 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. L40207 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.590in. ⁓1-19/32"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

3.120in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.590in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Winding Quantity
The number of individual /not electrically connected/ windings.

3

Coil Quantity
The number of coils included on the item.

2

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

150.0 ohms first winding

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

150.0 ohms second winding

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

20.0 ohms third winding

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

inert gas

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

polarized and latching contacts

Minimum Differential Electrical Operating Rating
The lowest net amount of the specified energizing electrical characteristic necessary for the normal functioning of the relay. the net value being the difference between multiple or opposed input elements during normal operation.

2.1 milliamperes

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

60.0 milliamperes dc inductive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

120.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

operating current type dc; includes damping coil to prevent contact bounce

Answers.

What is the overall width?

1.590 inches

What is the NSN for L40207?

5945-00-239-2413

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of L40207?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-239-2413 RELAY,ELECTROMAGNETIC

operating current type dc; includes damping coil to prevent contact bounce 1.590" overall width 1.590" overall length

NIIN
002392413
NIIN Date
01/01/63
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MM4377ALT4 Cage 77748
2. 7J0ZT Cage 78277

Major End Users Countries and entities

  • - Italy 
  • - Turkey 

Availability for L40207 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

L40207 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.