KL-D9A015

KLD9A015 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. KL-D9A015 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.000in. ⁓1/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.015in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.015in.

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

cass station, general electric

Winding Quantity
The number of individual /not electrically connected/ windings.

2

Coil Quantity
The number of coils included on the item.

2

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

450.0 ohms all windings

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

16 PLUG-In terminal single mounting facility

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

latching contacts

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

4 pole, double throw, both positions maintained

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

12.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

plug in terminals are 0.175 in. long.

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

30003-2037AS196 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

16 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.015 inches

What is the NSN for KL-D9A015?

5945-01-410-2919

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of KL-D9A015?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-410-2919 RELAY,ELECTROMAGNETIC

Used on cass station, general electric. plug in terminals are 0.175 in. long. 1.015" overall width 1.000" overall length

NIIN
014102919
NIIN Date
03/08/95
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
17 X 13 X 10
QUP
Historical Price
$1,559.20 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 2037AS196-02 Cage 30003
2. EL415-2061 Cage 99699
3. 10129663 Cage A486G

Major End Users Countries and entities

  • - Department of The Navy 
  • - Finland 

Availability for KL-D9A015 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

KL-D9A015 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.