KHS11D11-24V

KHS11D1124V Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. KHS11D11-24V specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a single mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand single mounting facility

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.312in. single mounting facility ⁓5/16"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.156in. ⁓1-5/32"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.593in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.910in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Contact Material
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.

silver

Contact Surface Treatment
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the contact surface.

gold flash

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

650.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded stud single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

48 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.099in. single mounting facility ⁓7/64"

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.006 seconds fixed release time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.013 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

24.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

3.0 amperes ac resistive load and 3.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

120.0 ac and 30.0 dc

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

900.0 milliwatts

Precious Material And Location
An indication of the precious material and its location in the item.

contacts silver and contact surfaces gold

Precious Material
Identification of the precious material contained in the item.

silver and gold

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 tab, solder lug all functions

Answers.

What class is the thread series?

Unc single mounting facility

What is the thread quantity per inch?

48 single mounting facility

What is the overall width?

0.910 inches maximum

What is the thread length?

0.312 inches single mounting facility

What is the thread direction?

Right-hand single mounting facility

What is the thread class?

2a single mounting facility

What is the NSN for KHS11D11-24V?

5945-00-257-9903

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of KHS11D11-24V?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-257-9903 RELAY,ELECTROMAGNETIC

unc single mounting facility thread series 48 single mounting facility thread quantity per inch 0.910" overall width 1.156" overall length 0.312" single mounting facility thread length right-hand single mounting facility 2a single mounting facility thread class

NIIN
002579903
NIIN Date
06/22/73
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
QUP
 
Historical Price
$47.08 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains combination of precious metals (silver, gold, platinum)
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 

Availability for KHS11D11-24V A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

KHS11D11-24V / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.