KB17AG115V60CPS

KB17AG115V60CPS Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. KB17AG115V60CPS specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.218in. ⁓3-7/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.611in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

1.375in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.310in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.827in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.156in. single mounting facility

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Contact Material
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.

silver

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 and 60.0

Winding Quantity
The number of individual /not electrically connected/ windings.

2

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

2

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

1.03 kilohms all windings

Duty Type
Indicates the type of duty provided.

intermittent

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 unthreaded hole single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

latching contacts

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

13.581 cubicin.

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

4 pole, double throw, one position momentary

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

44.0 milliamperes ac all windings

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.025 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

120.0 volts ac 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

5.0 VOLTS-Amperes

Precious Material And Location
An indication of the precious material and its location in the item.

contacts silver

Precious Material
Identification of the precious material contained in the item.

silver

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

16 tab, solder lug all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.827 inches maximum

What is the NSN for KB17AG115V60CPS?

5945-00-816-1627

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of KB17AG115V60CPS?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-816-1627 RELAY,ELECTROMAGNETIC

1.827" overall width 3.218" overall length

NIIN
008161627
NIIN Date
01/01/63
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
0.400lbs
Item Dimensions
--
QUP
Historical Price
$161.40 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 752S017 Cage 82152
2. 215426 Cage 0KDP7
3. 752-5017 Cage 00471
4. KB17AG-120 Cage 77342
5. KB17AG115VAC Cage 77342
6. 996862-01 Cage 35351
7. 30G8649 Cage 75491
8. 752-5017 Cage 50140
9. 752-5017 Cage 82152

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 
  • - Department of The Army 
  • - Department of The Air Force 
  • - Department of The Navy 
  • - Federal Aviation Administration 
  • - U.s. Coast Guard 
  • - Poland 
  • - Germany 
  • - Italy 
  • - Greece 
  • - Turkey 

Availability for KB17AG115V60CPS A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

KB17AG115V60CPS / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.