Datasheet. K0684 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.810in. ⁓13/16"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.617in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.410in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

shock resistant and vibration resistant

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

700.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

26.5 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

failure rate level 0.1 percent.

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-39016/6 government specification

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.410 inches maximum

What is the NSN for K0684?

5945-01-170-6307

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of K0684?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-170-6307 RELAY,ELECTROMAGNETIC

failure rate level 0.1 percent. 0.410" overall width 0.810" overall length

NIIN
011706307
NIIN Date
01/27/84
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$88.55 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 50GBDN-1-A-700 Cage 98927
2. 2K3470-2 Cage 02289
3. 35AV1087A2 Cage 01526
4. 3SAV5004H1 Cage 01526
5. M5757/9-003 Cage 02289
6. M39016/06-109P Cage 81349
7. M39016/06-209M Cage 81349
8. M39016/6-109 Cage 81349
9. M39016/6-109M Cage 81349
10. M39016/6-209M Cage 81349
11. M39016/6-209P Cage 81349
12. M5757/9-003 Cage 81349
13. M5757/9-004 Cage 81349
14. M39016/6-109P Cage 81349
15. MIL-PRF-39016/6 Cage 81349
16. 80500-2 Cage 07148
17. 90017-2 Cage 07148
18. 37056 Cage 04034
19. S6A1-26.5VDC Cage 1BU99
20. 06-00-0001 Cage 23210
21. 70030-4 Cage 66822
22. BACR13CK6 Cage 81205
23. 578R040H07 Cage 97942
24. 46004046-000 Cage 96238
25. HF1201K01 Cage 00779
26. BRA26A1P6AS9 Cage 99699
27. SX2484 Cage 02288
28. 36J700GSWN Cage 78277
29. FC1-581W Cage 78290
30. FC1P26-5VDC Cage 78290
31. 3SAV2193A2 Cage 1DUQ5
32. 755002A7677-1 Cage 87990
33. FC-1W-P26-5VDC Cage 78290
34. 2WK2A126 Cage 02289
35. 3SAV2193A2 Cage 01526
36. 454417 Cage 36378
37. MILR5757-9-003 Cage 81349
38. MILR5757-9-004 Cage 81349
39. 3SAV1859A2 Cage 1DUQ5
40. 2K2A126 Cage 02289
41. 3SAV1859A2 Cage 01526
42. M39016/6-209 Cage 81349
43. MIL-R-39016/6 Cage 81349
44. HF1201K01 Cage 1E9M5
45. HF1201K01 Cage 58614
46. 044634 Cage 89305
47. M5757-9-003 Cage D0080
48. 5945011706307 Cage SCY13
49. 10148480 Cage A486G
50. M39016/6-209L Cage 9Y507

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - National Security Agency 
  • - Federal Aviation Administration 
  • - U.s. Coast Guard 
  • - Austria 
  • - Finland 
  • - Lithuania 
  • - Poland 
  • - Bulgaria 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Morocco 
  • - Malaysia 
  • - Australia 
  • - Belgium 
  • - Canada 
  • - New Zealand 
  • - France 
  • - Germany 
  • - Republic of Korea 
  • - United Kingdom 
  • - Philippines 
  • - Netherlands 
  • - Portugal 
  • - Italy 
  • - Denmark 
  • - Norway 
  • - Greece 
  • - Turkey 
  • - Nato Maintenance And Supply Agency 

Availability for K0684 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

K0684 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.