Serving our customers with quality and safety first.
1.718in. ⁓1-23/32"
1.406in. single mounting facility
1.320in.
0.525in.
hermetic and shock resistant and vibration resistant
0.155in. single mounting facility and 0.161in. single mounting facility
1
1
continuous
2 unthreaded hole single mounting facility
polarized
1.190 cubicin.
IN-Line single mounting facility
2 pole, double throw, one position momentary
0.01 seconds fixed operate time
28.0 volts dc 25 deg celsius single winding
4.0 amperes ac motor load and 4.0 amperes dc motor load
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
115.0 ac and 28.0 dc
81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
8 wire hook all functions
96906-MS27744/1 government standard
On 04/30/1986 under contract DLA90086MBU48MODF0002 for qty 73
0.525 inches maximum
Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.525" overall width 1.718" overall length
1. | MS27744-1 | Cage 96906 |
2. | MIL-PRF-6106 | Cage 81349 |
3. | 499-037-034 | Cage 07421 |
4. | MIL-R-6106 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.