Serving our customers with quality and safety first.
1.718in. ⁓1-23/32"
1.280in.
0.525in.
hermetic
1
1
continuous
1 PLUG-In terminal single mounting facility
2 pole, double throw, one position momentary
0.01 seconds fixed operate time
28.0 volts dc 25 deg celsius single winding
8.0 amperes ac resistive load and 8.0 amperes dc resistive load
115.0 ac and 28.0 dc
81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
8 pin all functions
96906-MS-27744/2 government standard
0.525 inches maximum
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.525" overall width 1.718" overall length
1. | MS27744-2 | Cage 96906 |
2. | MIL-PRF-6106 | Cage 81349 |
3. | MIL-R-6106 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.