J-D2N

JD2N Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. J-D2N specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.718in. ⁓1-23/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.446in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.010in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.525in.

Mounting Slot Width
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.

0.150in. single mounting facility

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

320.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 bracket single mounting facility and 2 slotted hole single mounting facility

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

polarized

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

0.11 amperes dc single winding

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

4.0 amperes ac motor load and 4.0 amperes dc motor load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

8.0 amperes ac inductive load and 8.0 amperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load and 10.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes ac lamp load and 2.0 amperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

two pole, double throw contact

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 wire hook all functions

Answers.

What is the overall width?

0.525 inches maximum

What is the NSN for J-D2N?

5945-01-530-3230

How is this classified for shipping?

Schedule B number: 8536490050
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of J-D2N?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-530-3230 RELAY,ELECTROMAGNETIC

two pole, double throw contact 0.525" overall width 1.718" overall length

NIIN
015303230
NIIN Date
05/20/05
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Germany 

Availability for J-D2N A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

J-D2N / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.