Datasheet. HMS1201S006 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.810in. ⁓13/16"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.410in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.410in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

shock resistant and vibration resistant

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Contact Material
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.

gold

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

mm missile

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

2.64 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

0.136 cubicin.

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.005 seconds fixed release time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.006 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

36.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

750.0 milliamperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes ac resistive load and 2.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

1.2 watts

Precious Material And Location
An indication of the precious material and its location in the item.

terminals gold

Precious Material
Identification of the precious material contained in the item.

gold

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.410 inches maximum

What is the NSN for HMS1201S006?

5945-01-337-5508

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of HMS1201S006?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-337-5508 RELAY,ELECTROMAGNETIC

Used on mm missile. 0.410" overall width 0.810" overall length

NIIN
013375508
NIIN Date
04/17/91
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
Item Weight
0.400lbs
Item Dimensions
8 X 4 X 4
QUP
Historical Price
$113.30 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains gold
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

Major End Users Countries and entities

  • - Department of The Air Force 

Availability for HMS1201S006 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

HMS1201S006 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.