H8S16

H8S16 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. H8S16 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.750in. ⁓2-3/4"

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

1.063in. ⁓1-5/64"

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

265.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded bushing single mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.813in. single mounting facility ⁓53/64"

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

26.5 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

3.0 amperes ac resistive load and 3.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

12000.0 ac and 12000.0 dc

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

un single mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

5 pin all functions

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Un single mounting facility

What is the thread quantity per inch?

32 single mounting facility

What is the thread class?

2a single mounting facility

What is the NSN for H8S16?

5945-00-907-4861

How is this classified for shipping?

Schedule B number: 8537200020
nmfc 061300
Switchgear & switchboard assemblies for a voltage exceeding 1,000 v

What's the federal classification of H8S16?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-907-4861 RELAY,ELECTROMAGNETIC

un single mounting facility thread series 32 single mounting facility thread quantity per inch 2.750" overall length 2a single mounting facility thread class

NIIN
009074861
NIIN Date
01/01/60
Schedule B
8537200020 
Name Code
32512
FIIG
A03300
QUP
Historical Price
$307.38 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 746175 Cage 80045
2. 410-0378-000 Cage 13499
3. 1049636 Cage 59364
4. 412891-1 Cage 96214
5. RB1 Cage C4751
6. RB1E Cage C4751
7. RB1E26N161 Cage C4751
8. RB1E26N25 Cage C4751
9. RB1E26N300 Cage C4751
10. 11308928 Cage 17773
11. RB1E26N300 Cage 73905
12. 410-0378-000 Cage F5491
13. 410-0378-00 Cage 13499
14. RB1 Cage D1180
15. RB1E Cage D1180
16. RB1E26N161 Cage D1180
17. RB1E26N25 Cage D1180
18. RB1E26N300 Cage D1180
19. 1049636 Cage 77068
20. RB1E26N25 Cage 73905
21. RB1E26N161 Cage 73905
22. RB1 Cage 73905
23. RB1E Cage 73905
24. T8T Cage 21621

Major End Users Countries and entities

  • - Spain 
  • - Singapore 
  • - Canada 
  • - New Zealand 
  • - France 
  • - Germany 
  • - Republic of Korea 
  • - United Kingdom 
  • - Italy 
  • - Greece 
  • - Turkey 

Availability for H8S16 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Radio parts and equipment, excluding tubes packed separately 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

H8S16 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.