GX6692

GX6692 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. GX6692 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.320in. ⁓1-21/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.040in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.930in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

500.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

3 threaded hole single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

2c

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

triangle single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.

1.187in. single mounting facility

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

24.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

3.0 amperes ac resistive load and 3.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Answers.

What is the overall width?

0.930 inches

What is the NSN for GX6692?

5945-00-283-8760

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of GX6692?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-283-8760 RELAY,ELECTROMAGNETIC

0.930" overall width 1.320" overall length

NIIN
002838760
NIIN Date
01/01/63
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
QUP
 
Historical Price
$58.43 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 31955-1 Cage 96214
2. 22310-0 Cage 80089

Availability for GX6692 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

GX6692 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.