GT11348C11

GT11348C11 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. GT11348C11 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.090in. ⁓4-3/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

0.750in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.120in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Winding Quantity
The number of individual /not electrically connected/ windings.

2

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

1.0 kilohms first winding

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

1.2 kilohms second winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

2B1C1a

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.164in. single mounting facility ⁓11/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

16.1 milliamperes dc all windings

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

48.0 volts dc 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

50.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

50.0 dc

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

11 pin all functions

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc single mounting facility

What is the overall width?

2.120 inches

What is the thread class?

2b single mounting facility

What is the NSN for GT11348C11?

5945-00-913-9340

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of GT11348C11?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-913-9340 RELAY,ELECTROMAGNETIC

unc single mounting facility thread series 2.120" overall width 4.090" overall length 2b single mounting facility thread class

NIIN
009139340
NIIN Date
07/06/66
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$47.88 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Defense Logistics Agency 

Availability for GT11348C11 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

GT11348C11 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.