G616660-54

G61666054 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. G616660-54 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.750in. ⁓1-3/4"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

0.750in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.870in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.370in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

fungus resistant and shock resistant and water resistant

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

140.0 ohms single winding

Duty Type
Indicates the type of duty provided.

intermittent

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

1B3A and 1B2A

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.138in. single mounting facility ⁓9/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

40.0 milliamperes dc single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes ac resistive load and 2.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

10.0 ac and 26.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

bell telephone varistor part no. GA52018 included

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

16 pin all functions

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc single mounting facility

What is the thread quantity per inch?

32 single mounting facility

What is the overall width?

1.370 inches

What is the thread class?

2b single mounting facility

What is the NSN for G616660-54?

5945-00-259-0912

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of G616660-54?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-259-0912 RELAY,ELECTROMAGNETIC

unc single mounting facility thread series bell telephone varistor part no. GA52018 included 32 single mounting facility thread quantity per inch 1.370" overall width 1.750" overall length 2b single mounting facility thread class

NIIN
002590912
NIIN Date
01/01/63
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$163.43 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. G616660 Cage 71482
2. 1088888-54 Cage 10001
3. X8396 Cage 00779
4. X8396 Cage D0080
5. 12Z13001-9640 Cage 94135
6. G61660-54 Cage 01714
7. GA53566L54 Cage 01714
8. GA50711L54 Cage 01714
9. X8396 Cage 58614
10. G616660 Cage 1E9M5

Major End Users Countries and entities

  • - Department of The Navy 
  • - France 
  • - Italy 
  • - Greece 

Availability for G616660-54 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

G616660-54 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.