Datasheet. FB201005V ITEM 190 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.750in. ⁓1-3/4"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

0.500in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

1.375in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.562in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.156in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.005 seconds fixed release time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.013 seconds fixed operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

115.0 volts ac 25 deg celsius all windings and 30.0 volts dc 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 wire hook all functions

Answers.

What is the NSN for FB201005V ITEM 190?

5945-00-009-5551

How is this classified for shipping?

Schedule B number: 8536490075
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of FB201005V ITEM 190?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-009-5551 RELAY,ELECTROMAGNETIC

1.750" overall length

NIIN
000095551
NIIN Date
07/29/72
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
QUP
 
Historical Price
$80.00 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. FB201005V-190 Cage U1381
2. 2TR1B215 Cage 02289
3. 2TR1B215 Cage U0864
4. FB201005V-190 Cage U5295

Major End Users Countries and entities

  • - Federal Aviation Administration 
  • - Canada 
  • - New Zealand 
  • - United Kingdom 
  • - Greece 

Availability for FB201005V ITEM 190 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

FB201005V ITEM 190 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.