ER432TM4-26B

ER432TM426B Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. ER432TM4-26B specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

0.562in. ⁓9/16"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.370in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.370in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic and shock resistant

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

delicate

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

3.3 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 printed circuit terminal single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

ciruclar single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

9.5 milliamperes dc single winding

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.004 seconds fixed operate time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.007 seconds fixed release time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

200.0 milliamperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

1.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 milliamperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Part Name Assigned By Controlling Agency
The name assigned to the item by the government agency or commercial organization controlling the design of the item.

teledyne established reliability relay series 432

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

432t dpdt relay with internal transistor driver and coil transient suppression diode

Precious Material And Location
An indication of the precious material and its location in the item.

contact finish gold

Precious Material
Identification of the precious material contained in the item.

gold

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

10 pin all functions

Answers.

What is the overall width?

0.370 inches

What is the NSN for ER432TM4-26B?

5945-01-626-6018

What's the federal classification of ER432TM4-26B?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-626-6018 RELAY,ELECTROMAGNETIC

432t dpdt relay with internal transistor driver teledyne established reliability relay series 432 0.370" overall width 0.562" overall length

NIIN
016266018
NIIN Date
03/17/14
Schedule B
 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code )
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
--
Enviromental
N/A
Electrostatic ESD & EMI
Has ESD sensitivity

Major End Users Countries and entities

  • - Department of The Navy 

Availability for ER432TM4-26B A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

ER432TM4-26B / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.