DC10526

DC10526 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. DC10526 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.120in. ⁓2-1/8"

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

1.750in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.420in. and 2.560in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.120in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.200in. single mounting facility and 0.218in. single mounting facility

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

SH2F-dcn

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

11.506 cubicin.

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

diagonal single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes dc resistive load

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

relay has two time delay outputs; output 1: 4.0 seconds to 6.0 seconds; output 2: 20.0 seconds to 30.0 seconds

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

1 connector, plug all functions

Answers.

What is the overall width?

2.120 inches

What is the NSN for DC10526?

5945-01-311-4649

What's the federal classification of DC10526?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-311-4649 RELAY,ELECTROMAGNETIC

Used on sh2f-dcn. relay has two time delay outputs; output 1: 4.0 seconds to 6.0 seconds; output 2: 20.0 seconds to 30.0 seconds 2.120" overall width 2.120" overall length

NIIN
013114649
NIIN Date
11/29/89
Schedule B
 
Name Code
32512
FIIG
A03300
Item Weight
0.300lbs
Item Dimensions
21 X 20 X 26
QUP
 
Historical Price
$10,620.75 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 10526 Cage 73030
2. 10526 Cage 07148

Major End Users Countries and entities

  • - Department of The Navy 
  • - New Zealand 

Availability for DC10526 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

DC10526 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.