CAD14A10/110

CAD14A10110 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. CAD14A10/110 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.406in. ⁓1-13/32"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.281in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.406in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Contact Material
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.

silver

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

2.25 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

5.931 cubicin.

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

3 pole, double throw, one position momentary

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

17.5 milliamperes ac single winding

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.01 seconds fixed operate time

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.015 seconds fixed release time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

120.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load and 10.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

120.0 ac and 28.0 dc

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

3.0 watts

Precious Material And Location
An indication of the precious material and its location in the item.

contacts silver

Precious Material
Identification of the precious material contained in the item.

silver

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

1 standard tube base all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.406 inches maximum

What is the NSN for CAD14A10/110?

5945-00-839-7511

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of CAD14A10/110?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-839-7511 RELAY,ELECTROMAGNETIC

1.406" overall width 1.406" overall length

NIIN
008397511
NIIN Date
01/01/60
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
0.300lbs
Item Dimensions
QUP
Historical Price
$42.20 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. KAP14AG120V Cage 12300
2. 140103042 Cage 31795
3. 390932 Cage 1PQF4
4. 13C36A115 Cage 58614
5. 180680-2 Cage 03956
6. 1551AS251-1 Cage 30003
7. 8501KP-13120V-60HZ Cage 51918
8. KRP-14AG Cage 77342
9. KRP14A120VAC60HZ Cage 77342
10. KRPA14AG-120VAC Cage 77342
11. 533045-30 Cage 96214
12. 27446 Cage 78702
13. 540-103-062 Cage 31795
14. RM84-13-115 Cage 61275
15. 400-2365-101 Cage 0ZW37
16. 13010 Cage 90598
17. 323A10-115 Cage 93790
18. KRP14AG120 Cage 77342
19. KRP14AG115 Cage 77342
20. A123674 Cage 34875
21. 8501KP13V20 Cage 56365
22. 956C465-3 Cage 99167
23. MK3P5-S Cage 31795
24. 034001-0008 Cage 14210
25. 6-1393104-5 Cage Z3940
26. 9-1393101-6 Cage Z3940
27. KRP-14AG-120 Cage Z3940
28. KRPA-14AG-120 Cage Z3940
29. KRP14AG120 Cage F0595
30. MKH3A-120 Cage 07065
31. CDR303CPEKN-115A Cage 93790
32. W88ACPX-12 Cage 94696
33. 155-93T200 Cage 04221
34. 314XCX48P120VAC Cage 78290
35. A314XCX48P120V Cage 78290
36. KRP14A115 Cage 12300
37. 956C465-3 Cage 83843
38. 45005 Cage 26699
39. 390932 Cage 36378
40. 13C36A115 Cage 82415
41. 21F1097 Cage 77342
42. KRP14AG-120VAC Cage 77342
43. KAP14AG-110V Cage 77342
44. KAP14AG-120V Cage 77342
45. KRPA14AG120 Cage 77342
46. 400-2365-101 Cage 32153
47. SKP14AG110 Cage 12034
48. CAD14A5-110 Cage 61725

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 
  • - National Aeronautics And Space Administration 
  • - Bureau of Engraving And Printing 
  • - U.s. Postal Service - Procurement And Supplies Department 
  • - Department of The Army 
  • - Department of The Navy 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - National Security Agency 
  • - Federal Aviation Administration 
  • - U.s. Coast Guard 
  • - Poland 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Thailand 
  • - Australia 
  • - Belgium 
  • - Canada 
  • - France 
  • - Republic of Korea 
  • - Netherlands 
  • - Portugal 
  • - Norway 
  • - Greece 
  • - Turkey 
  • - Nato Maintenance And Supply Agency 

Availability for CAD14A10/110 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

CAD14A10/110 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.