C1087709

C1087709 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. C1087709 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b single mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.060in. ⁓2-1/16"

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

0.750in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.280in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.060in.

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

5.0 kilohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

1a

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.138in. single mounting facility ⁓9/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

120.0 milliamperes dc single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

50.0 milliamperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

550.0 dc

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab, solder lug contacts

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab, solder lug energizing element

Answers.

What class is the thread series?

Unc single mounting facility

What is the thread quantity per inch?

32 single mounting facility

What is the overall width?

1.060 inches

What is the thread direction?

Right-hand single mounting facility

What is the thread class?

2b single mounting facility

What is the NSN for C1087709?

5945-00-020-9999

How is this classified for shipping?

Schedule B number: 8536410050
Relays, electromechanical, for a voltage not exceeding 60 v

What's the federal classification of C1087709?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-020-9999 RELAY,ELECTROMAGNETIC

unc single mounting facility thread series 32 single mounting facility thread quantity per inch 1.060" overall width 2.060" overall length right-hand single mounting facility 2b single mounting facility thread class

NIIN
000209999
NIIN Date
04/29/67
Schedule B
8536410050 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
--
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. SK0328622F Cage 82415

Availability for C1087709 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

C1087709 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.