BR64-S155

BR64S155 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. BR64-S155 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.718in. ⁓1-23/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.446in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.300in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.515in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.150in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

320.0 ohms single winding

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

4.0 amperes ac motor load and 4.0 amperes dc motor load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

8.0 amperes ac inductive load and 8.0 amperes dc inductive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load and 10.0 amperes dc resistive load

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

2.0 amperes ac lamp load and 2.0 amperes dc lamp load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac and 28.0 dc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Answers.

What is the overall width?

0.515 inches

What is the NSN for BR64-S155?

5945-01-115-1972

How is this classified for shipping?

Schedule B number: 8536490075
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of BR64-S155?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-115-1972 RELAY,ELECTROMAGNETIC

0.515" overall width 1.718" overall length

NIIN
011151972
NIIN Date
06/30/81
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. J-D4A-038 Cage 58657
2. T503004702 Cage 36090

Major End Users Countries and entities

  • - Canada 

Availability for BR64-S155 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

BR64-S155 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.