A40A1891

A40A1891 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. A40A1891 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

5.250in. ⁓5-1/4"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

4.500in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.620in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.870in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.120in. single mounting facility

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

type no. G-1

Winding Quantity
The number of individual /not electrically connected/ windings.

2

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

2

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

13.6 ohms second winding

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

14.5 ohms first winding

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

magnetic

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

2c

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

latching contacts

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

25.722 cubicin.

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius all windings

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

10 tab, solder lug all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.870 inches

What is the NSN for A40A1891?

5945-00-259-1321

What's the federal classification of A40A1891?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-259-1321 RELAY,ELECTROMAGNETIC

Used on type no. g-1. 1.870" overall width 5.250" overall length

NIIN
002591321
NIIN Date
01/01/61
Schedule B
 
Name Code
32512
FIIG
A03300
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$1,435.00 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 40A1891 Cage 99167

Major End Users Countries and entities

  • - Poland 
  • - South Africa 
  • - Turkey 

Availability for A40A1891 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

A40A1891 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.