A-885Y

A885Y Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. A-885Y specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.660in. ⁓4-43/64"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

4.250in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

2.125in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.880in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.660in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.196in. single mounting facility

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

helicopter, MH-53E; helicopter, sof/HH-53H pave low; helicopter, super jolly H-53; helicopter, CH-53A/d/e; helicopter, RH-53

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, double throw, one position momentary

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

28.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

100.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

28.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

weapon system essential

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

5 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

2.660 inches

What is the NSN for A-885Y?

5945-00-999-4896

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of A-885Y?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-999-4896 RELAY,ELECTROMAGNETIC

Used on helicopter, mh-53e; helicopter, sof/hh-53h pave low; helicopter, super jolly h-53; helicopter, ch-53a/d/e; helicopter, rh-53. weapon system essential 2.660" overall width 4.660" overall length

NIIN
009994896
NIIN Date
02/16/66
Schedule B
8536410020 
Name Code
32512
FIIG
A03300
Item Weight
0.700lbs
Item Dimensions
47 X 27 X 29
QUP
Historical Price
$2,315.63 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. G-1032-A885Y-C Cage 0U8Z9
2. A-885-1779 Cage 52401
3. SD146 Cage 74063

Major End Users Countries and entities

  • - Department of The Army 
  • - Department of The Navy 
  • - Department of The Air Force 
  • - Austria 
  • - Brazil 
  • - Canada 
  • - Germany 

Availability for A-885Y A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

A-885Y / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.