Serving our customers with quality and safety first.
2.187in. ⁓2-3/16"
1.844in. single mounting facility
2.156in.
0.687in.
metal
hermetic
0.147in. single mounting facility
moderately rugged
60.0
1
general
1
continuous
air
2 unthreaded hole single mounting facility
general purpose warehouse
3.239 cubicin.
IN-Line single mounting facility
2 pole, double throw, one position momentary
0.025 seconds fixed operate time
0.05 seconds fixed release time
115.0 volts ac 25 deg celsius single winding
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
800.0 milliamperes ac lamp load and 800.0 milliamperes dc lamp load
1.5 amperes ac motor load and 1.5 amperes dc motor load
115.0 ac and 28.0 dc
81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
8 pin all functions
96906-MS25321 government standard
1EA
0.687 inches maximum
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.687" overall width 2.187" overall length
1. | MS25321-A3 | Cage 96906 |
2. | MIL-PRF-6106 | Cage 81349 |
3. | 229-4618 | Cage 58657 |
4. | MIL-R-6106 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.