889590

889590 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 889590 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

9.430in. ⁓9-7/16"

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

4.625in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

6.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

5.250in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.281in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Height
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.

5.125in. single mounting facility

Winding Quantity
The number of individual /not electrically connected/ windings.

2

Coil Quantity
The number of coils included on the item.

2

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

1.3 kilohms second winding

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

150.0 ohms first winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

700.0 milliamperes dc single winding

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

115.0 volts dc 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

15.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

1500.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

arc quenching method: vacuum

Answers.

What is the overall width?

5.250 inches

What is the NSN for 889590?

5945-00-790-4885

How is this classified for shipping?

Schedule B number: 8537200020
nmfc 061300
Switchgear & switchboard assemblies for a voltage exceeding 1,000 v

What's the federal classification of 889590?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-790-4885 RELAY,ELECTROMAGNETIC

arc quenching method: vacuum 5.250" overall width 9.430" overall length

NIIN
007904885
NIIN Date
01/01/63
Schedule B
8537200020 
Name Code
32512
FIIG
A03300
Item Weight
18.600lbs
Item Dimensions
120 X 85 X 78
QUP
 
Historical Price
$3,707.50 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Department of The Navy 
  • - Spain 
  • - Republic of Korea 
  • - Italy 
  • - Turkey 

Availability for 889590 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

889590 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.