Serving our customers with quality and safety first.
0.385in. ⁓25/64"
0.370in. ⁓3/8"
1
1
100.0 ohms single winding
continuous
1 PLUG-In terminal single mounting facility
polarized and coil voltage suppression
2 pole, double throw, one position momentary
0.006 seconds fixed operate time
0.0075 seconds fixed release time
5.0 volts dc 25 deg celsius single winding
200.0 milliamperes ac resistive load and 1.0 amperes dc resistive load
115.0 ac and 28.0 dc
supplied with spreader pad
8 pin all functions
1EA
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
supplied with spreader pad 0.385" overall length
1. | 923647-1 | Cage 06481 |
2. | 3501-101 | Cage K0662 |
3. | 745220-08 | Cage 35351 |
4. | CSWD-5S2 | Cage 02289 |
5. | 3501-101 | Cage U3755 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.