7012PDB

7012PDB Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 7012PDB specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b second mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand second mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.250in. ⁓3-1/4"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

2.880in. first mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

1.750in. second mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

4.520in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

3.090in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.199in. first mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Height
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.

0.750in. first mounting facility and 1.500in. first mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Height
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.

0.500in. second mounting facility

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 threaded hole second mounting facility

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

6 unthreaded hole first mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

45.392 cubicin.

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 second mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.164in. second mounting facility ⁓11/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular first mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

rectangular second mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

5.00 seconds adjustable operate time and 50.00 seconds adjustable operate time

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

125.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load and 15.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

240.0 ac and 30.0 dc

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

8.0 watts

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc second mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 screw all functions

Answers.

What class is the thread series?

Unc second mounting facility

What is the thread quantity per inch?

32 second mounting facility

What is the overall width?

3.090 inches maximum

What is the thread direction?

Right-hand second mounting facility

What is the thread class?

2b second mounting facility

What is the NSN for 7012PDB?

5945-01-080-0765

How is this classified for shipping?

Schedule B number: 8536490075
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of 7012PDB?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-080-0765 RELAY,ELECTROMAGNETIC

unc second mounting facility thread series 32 second mounting facility thread quantity per inch 3.090" overall width 3.250" overall length right-hand second mounting facility 2b second mounting facility thread class

NIIN
010800765
NIIN Date
07/19/79
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - France 

Availability for 7012PDB A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

7012PDB / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.