6000-1002-1002475ALT1LINE415

600010021002475ALT1LINE415 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 6000-1002-1002475ALT1LINE415 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

6.000in. ⁓6-1/64"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

5.438in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

3.120in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.500in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.173in. single mounting facility

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

110.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole single mounting facility

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, single throw, normally open, momentary action and 2 pole, single throw, normally closed, momentary action

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

105.0 milliamperes ac single winding

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

115.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

25.0 amperes ac resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

115.0 ac

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

2.500 inches

What is the NSN for 6000-1002-1002475ALT1LINE415?

5945-00-295-6616

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of 6000-1002-1002475ALT1LINE415?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-295-6616 RELAY,ELECTROMAGNETIC

2.500" overall width 6.000" overall length

NIIN
002956616
NIIN Date
01/01/63
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$330.33 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 4195-02LINE149SH2 Cage 81994
2. 4195-02LINE154SH2 Cage 81994
3. 4195-02LINE174SH2 Cage 81994
4. 26527-7-5 Cage 63743
5. K43307 Cage 63743
6. 240-6504-1035771REVAPC35 Cage 80064
7. 240-6504-1035773REVAPC24 Cage 80064
8. 240-6504-1035774REVAPC21 Cage 80064
9. 240-6504-1036863REVAPC35 Cage 80064
10. 282-6504-803099PC15 Cage 80064
11. 319-3101-1183779LINE141 Cage 80064
12. 319-3101-1183779LINE153 Cage 80064
13. 319-3101-1183779LINE168 Cage 80064
14. 319-6505-1183942PC16 Cage 80064
15. 319-6505-1183943PC15 Cage 80064
16. 319-6505-1183945PC11 Cage 80064
17. 320-6505-798938PC16 Cage 80064
18. 320-6505-798938REVCPC16 Cage 80064
19. 320-6505-798940REVCPC11 Cage 80064
20. 320-6505-798941PC15 Cage 80064
21. 340-6000-1002475ALT1LINE338 Cage 80064
22. 340-6000-1002475ALT1LINE348 Cage 80064
23. 340-6000-1002475ALT1LINE356 Cage 80064
24. 340-6504-1002308PC27 Cage 80064
25. 340-6504-1002309PC21 Cage 80064
26. 340-6504-1002310PC5 Cage 80064
27. 340-6505-1002815PC2 Cage 80064
28. 344-6201-937770ALT2PC15 Cage 80064
29. 346-6201-680659PC15 Cage 80064
30. 362-6505-793652PC15 Cage 80064
31. 366-3100-1425516LINE149SH2 Cage 80064
32. 366-3100-1425516LINE159SH2 Cage 80064
33. 366-3100-1425516LINE174SH2 Cage 80064
34. K1-3101-1001284ALT2LINE220 Cage 80064
35. K1-6505-1001441ALT1MARK20 Cage 80064
36. 564-3101-937728LINE197 Cage 80064
37. 564-3101-937728LINE211 Cage 80064
38. 564-6505-937841ALT1PC6 Cage 80064
39. 564-6505-938110ALT3PC20 Cage 80064
40. 564-6505-938111ALT1PC5 Cage 80064
41. 564-6505-938111ALT2PC5 Cage 80064
42. 564-6505-938111PC15 Cage 80064
43. 564-6505-938111PC5 Cage 80064
44. 571-6202-1301776REVALINE543 Cage 80064
45. 571-6504-1301660REVBPC5 Cage 80064
46. 575-6504-1443398PC5 Cage 80064
47. 3667-32REVBPC5 Cage 96169
48. 3695-03REVALINE543 Cage 96169
49. 3767-32PC5 Cage 96169
50. 2967-03PC20 Cage 96169
51. 2767-51PC15 Cage 96169
52. 2995-03LINE197 Cage 96169
53. 2995-03LINE211 Cage 96169
54. 2967-40ALT1PC6 Cage 96169
55. 2967-47ALT1PC5 Cage 96169
56. 2967-47ALT2PC5 Cage 96169
57. 2967-47PC15 Cage 96169
58. 3095-03LINE220 Cage 96169
59. 3067-39MARK20 Cage 96169
60. 3367-13PC16 Cage 96169
61. 3367-14PC15 Cage 96169
62. 3367-25PC11 Cage 96169
63. 3395-02LINE153SH2 Cage 96169
64. 3395-02LINE168SH2 Cage 96169
65. 3867-15PC27 Cage 96169
66. 3867-16PC21 Cage 96169
67. 3867-17PC5 Cage 96169
68. 3867-22PC2 Cage 96169
69. 3895-03ALT1LINE338 Cage 96169
70. 3895-03ALT1LINE348 Cage 96169
71. 3895-03ALT1LINE356 Cage 96169
72. 3895-03ALT1LINE415 Cage 96169
73. 4195-02LINE174SH2 Cage 96169
74. 4195-02LINE149SH2 Cage 96169
75. 4195-02LINE154SH2 Cage 96169

Major End Users Countries and entities

  • - Department of The Navy 
  • - Spain 
  • - Belgium 
  • - Italy 
  • - Turkey 

Availability for 6000-1002-1002475ALT1LINE415 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

6000-1002-1002475ALT1LINE415 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.