5189316

5189316 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 5189316 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a single mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.660in. ⁓2-43/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.230in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.250in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

hermetic

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

3 threaded stud single mounting facility

Pile-up Main Contact Form Arrangement
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.

2c

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.138in. single mounting facility ⁓9/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

triangle single mounting facility

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

135.0 milliamperes dc all windings

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

0.005 seconds adjustable operate time and 0.500 seconds adjustable operate time

Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.

0.625in. single mounting facility

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

31.0 volts dc 25 deg celsius all windings

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc single mounting facility

What is the thread quantity per inch?

32 single mounting facility

What is the overall width?

1.250 inches

What is the thread direction?

Right-hand single mounting facility

What is the thread class?

2a single mounting facility

What is the NSN for 5189316?

5945-01-166-7124

What's the federal classification of 5189316?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-166-7124 RELAY,ELECTROMAGNETIC

unc single mounting facility thread series 32 single mounting facility thread quantity per inch 1.250" overall width 2.660" overall length right-hand single mounting facility 2a single mounting facility thread class

NIIN
011667124
NIIN Date
11/16/83
Schedule B
 
Name Code
32512
FIIG
A03300
Item Weight
1.000lbs
Item Dimensions
--
QUP
Historical Price
$852.88 EA
DEMIL / ITAR
USML/ITAR controlled item (Code: B)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 1700-S991 Cage 02289

Major End Users Countries and entities

  • - Department of The Navy 
  • - Poland 
  • - Brazil 
  • - Spain 
  • - Malaysia 
  • - Australia 
  • - Canada 
  • - Greece 
  • - Turkey 

Availability for 5189316 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

5189316 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.