Serving our customers with quality and safety first.
0.560in. ⁓9/16"
0.230in.
0.500in.
hermetic
1
1
1.8 kilohms single winding
continuous
1 PLUG-In terminal single mounting facility
2 pole, double throw, one position momentary
32.0 volts dc 25 deg celsius single winding
300.0 milliamperes ac resistive load and 500.0 milliamperes dc resistive load
115.0 ac and 26.5 dc
8 pin all functions
1EA
0.500 inches
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.500" overall width 0.560" overall length
1. | 90161301-99 | Cage 99699 |
2. | 1001P01 | Cage 71482 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.