43C4-128

43C4128 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 43C4-128 specification

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.138in. single mounting facility ⁓9/64"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.920in. ⁓1-59/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.375in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.468in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

intermittent

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded stud single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

120.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

5.0 amperes ac resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

120.0 ac

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

8 tab, solder lug all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.468 inches

What is the thread length?

0.138 inches single mounting facility

What is the NSN for 43C4-128?

5945-01-376-4465

How is this classified for shipping?

Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v

What's the federal classification of 43C4-128?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-376-4465 RELAY,ELECTROMAGNETIC

1.468" overall width 1.920" overall length 0.138" single mounting facility thread length

NIIN
013764465
NIIN Date
06/03/93
Schedule B
8536490050 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
19 X 17 X 15
QUP
Historical Price
$308.53 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Department of The Air Force 

Availability for 43C4-128 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

43C4-128 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.