Serving our customers with quality and safety first.
1.320in. and 1.330in. ⁓1-11/32"
1.073in. first mounting facility and 1.083in. first mounting facility
0.890in. and 0.900in.
0.390in. and 0.400in.
hermetic
0.115in. first mounting facility and 0.125in. first mounting facility
moderately rugged
1
1
8.0 kilohms single winding and 12.0 kilohms single winding
continuous
air
1 PLUG-In terminal second mounting facility
2 unthreaded hole first mounting facility
general purpose warehouse
0.468 cubicin.
IN-Line first mounting facility
2 pole, double throw, one position momentary
6.3 milliamperes dc single winding
0.004 seconds fixed release time
0.005 seconds fixed operate time
114.0 volts dc 25 deg celsius single winding
1.0 amperes ac resistive load and 2.0 amperes dc resistive load
1.0 amperes dc inductive load
115.0 ac and 28.0 dc
8 pin all functions
1EA
0.390 inches minimum and 0.400 inches maximum
Schedule B number: 8536490050
nmfc 061300
Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
0.390" overall width 1.320" overall length
1. | WKJ0-6D115VDC | Cage 02288 |
2. | 32213WKJ0-6D | Cage 27777 |
3. | 3SAF5135T1 | Cage 1DUQ5 |
4. | 3SAF5135T1 | Cage 01526 |
Nothing similar to this part number was found in our inventory
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.