269-639

269639 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 269-639 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.220in. ⁓2-15/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.220in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.525in.

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

used in switching unit model 940 onboard 210 ft wmec coast guard vessels

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 PLUG-In terminal single mounting facility

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

7.516 cubicin.

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

2 pole, double throw, one position momentary

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

110.0 volts dc 25 deg celsius single winding

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

9 quick disconnect, male contacts

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 quick disconnect, male energizing element

Answers.

What quantity is this sold in?

1EA

What is the overall width?

1.525 inches

What is the NSN for 269-639?

5945-01-233-2326

What's the federal classification of 269-639?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-233-2326 RELAY,ELECTROMAGNETIC

Used on used in switching unit model 940 onboard 210 ft wmec coast guard vessels. 1.525" overall width 2.220" overall length

NIIN
012332326
NIIN Date
05/28/86
Schedule B
 
Name Code
32512
FIIG
A03300
QUP
Historical Price
$105.88 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 
  • - U.s. Coast Guard 
  • - Canada 

Availability for 269-639 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

269-639 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.