13229E1248-3

13229E12483 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 13229E1248-3 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.531in. ⁓3-17/32"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

3.125in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

3.844in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.250in.

Mounting Slot Width
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.

0.196in. single mounting facility

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

4610-01-219-8707

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 slotted hole single mounting facility

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

IN-Line single mounting facility

Nonpile-up Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.

1 pole, single throw, normally open, momentary action

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

1.15 amperes dc single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

10.0 amperes ac resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

120.0 ac

Precious Material And Location
An indication of the precious material and its location in the item.

contact surfaces silver

Precious Material
Identification of the precious material contained in the item.

silver

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 screw all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

2.250 inches

What is the NSN for 13229E1248-3?

5945-01-348-5785

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of 13229E1248-3?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-348-5785 RELAY,ELECTROMAGNETIC

Used on 4610-01-219-8707. 2.250" overall width 3.531" overall length

NIIN
013485785
NIIN Date
11/13/91
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
1.500lbs
Item Dimensions
38 X 35 X 25
QUP
Historical Price
$353.53 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 700-NX105 Cage 01121

Major End Users Countries and entities

  • - Department of The Army 

Availability for 13229E1248-3 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

13229E1248-3 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.