124-114111-3

1241141113 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 124-114111-3 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a fourth mounting facility

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a first mounting facility

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a second mounting facility

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a third mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand first mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand fourth mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand second mounting facility

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand third mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.619in. ⁓3-5/8"

Coil Quantity
The number of coils included on the item.

1

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 bracket single mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

24 first mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

24 second mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 fourth mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 third mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.190in. fourth mounting facility ⁓13/64"

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.190in. third mounting facility ⁓13/64"

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.312in. first mounting facility ⁓5/16"

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.312in. second mounting facility ⁓5/16"

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

24.0 volts dc 25 deg celsius all windings

Precious Material And Location
An indication of the precious material and its location in the item.

contacts silver

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf first mounting facility

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf fourth mounting facility

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf second mounting facility

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf third mounting facility

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 threaded stud contacts

Answers.

What class is the thread series?

Unf third mounting facility

What class is the thread series?

Unf second mounting facility

What class is the thread series?

Unf fourth mounting facility

What class is the thread series?

Unf first mounting facility

What is the thread quantity per inch?

32 third mounting facility

What is the thread quantity per inch?

32 fourth mounting facility

What is the thread quantity per inch?

24 second mounting facility

What is the thread quantity per inch?

24 first mounting facility

What is the thread direction?

Right-hand third mounting facility

What is the thread direction?

Right-hand second mounting facility

What is the thread direction?

Right-hand fourth mounting facility

What is the thread direction?

Right-hand first mounting facility

What is the thread class?

2a third mounting facility

What is the thread class?

2a second mounting facility

What is the thread class?

2a first mounting facility

What is the thread class?

2a fourth mounting facility

What is the NSN for 124-114111-3?

5945-01-594-6431

What's the federal classification of 124-114111-3?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-594-6431 RELAY,ELECTROMAGNETIC

unf third mounting facility thread series 32 third mounting facility thread quantity per inch 3.619" overall length right-hand third mounting facility 2a third mounting facility thread class

NIIN
015946431
NIIN Date
04/25/11
Schedule B
 
Name Code
32512
FIIG
A03300
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. CA0045 Cage Z0FP9

Major End Users Countries and entities

  • - Australia 

Availability for 124-114111-3 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

124-114111-3 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.