11365-18-9

11365189 Electromagnetic Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 11365-18-9 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a first mounting facility

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a second mounting facility

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

2.250in. second mounting facility ⁓2-1/4"

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

1.750in. first mounting facility ⁓1-3/4"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

7.000in. ⁓7-1/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

7.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

4.370in.

Winding Quantity
The number of individual /not electrically connected/ windings.

1

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

770.0 ohms single winding

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded stud first mounting facility

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded stud second mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. first mounting facility ⁓1/4"

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.312in. second mounting facility ⁓5/16"

Nominal Operating Current Rating And Type
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.

120.0 milliamperes dc single winding

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

95.0 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

25.0 amperes dc inductive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

230.0 dc

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

a. equipped with two blowout assemblies

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc first mounting facility

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc second mounting facility

Fsc Application Data (non-core)
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.

1. except engine

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc second mounting facility

What class is the thread series?

Unc first mounting facility

What is the overall width?

4.370 inches

What is the thread length?

1.750 inches first mounting facility

What is the thread length?

2.250 inches second mounting facility

What is the thread class?

2a second mounting facility

What is the thread class?

2a first mounting facility

What is the NSN for 11365-18-9?

5945-00-552-5471

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of 11365-18-9?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-552-5471 RELAY,ELECTROMAGNETIC

unc second mounting facility thread series a. equipped with two blowout assemblies 4.370" overall width 7.000" overall length 1.750" first mounting facility thread length 2a second mounting facility thread class

NIIN
005525471
NIIN Date
01/01/63
Schedule B
8536490075 
Name Code
32512
FIIG
A03300
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$489.13 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 11365-275-9 Cage 63743
2. 16684FPCBM3 Cage 63743
3. 16684GPCBM3 Cage 63743
4. 285-4501-68053PCBM3 Cage 80064

Major End Users Countries and entities

  • - Department of The Navy 
  • - Spain 
  • - Turkey 

Availability for 11365-18-9 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

11365-18-9 / Relay,electromagneticWhat is the formal definition of this item?

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). includes solenoid and armature types. excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.