Serving our customers with quality and safety first.
2310-01-123-1610
intermittent duty pull solenoid; pull force: 5 lbs at .25in. stroke with 20 vdc applied at 165 degrees f with internal spring installed; internal SPRING-Coil unergized; spring force at gauge height: 2.15 lbs +OR- .25 lbs; spring force at engergized position: 13 lbs +OR- .50 lbs; operating voltage range: 20 to 30 vdc; coil resistance at 76 degrees f: 2.85 ohms and 3.15 ohms ; insulation resistance: 500 megohms at 1500 vdc coil to ground; duty (intermittent) at 165 degrees f: .5 minutes on; 3 minutes off; repeated 4 times; operating temperature range: -65 degrees f to 165 degrees f; meets MIL-S-4040 requirements
1EA
Schedule B number: 8412909080
nmfc 063100
Parts of engines and motors
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
Used on 2310-01-123-1610. intermittent duty pull solenoid; pull force: 5 lbs at .25" stroke with 20 vdc applied at 165 degrees f with internal spring installed; internal spring-coil unergized; spring force at gauge height: 2.15 lbs +or- .25 lbs; spring force at engergized position: 13 lbs +or- .50 lbs; operating voltage range: 20 to 30 vdc; coil resistance at 76 degrees f: 2.85 ohms
1. | 92007A0125 | Cage 01365 |
Nothing similar to this part number was found in our inventory
An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.